Permit: T01MH00523

Parcel: 10706002D

Inspection Status: Approved

Inspection History: MOBILE HOME ELECTRICAL

Permit Number - T01MH00523

Inspection Description - MOBILE HOME ELECTRICAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/14/2001 MOBILE HOME ELECTRICAL Approved AC DUCT MUST BE 4" ABOVE EARTH.
11/26/2001 MOBILE HOME ELECTRICAL Partial Approval IVRS - Inspection 0000*1.) DOUBLE LUGING AT MAIN PANEL 2.) SPLIT BOLT HAS TO MANY CONDUCTOR; SHOULD BE RUN & TAP ONLY. (CHECK INTO REPLACING SPLIT BOLT WITH A MULTI LUG ASSEMBLY. 3.) FEEDER JUMPERS UNDERSIZED.
11/20/2001 MOBILE HOME ELECTRICAL Denied IVRS - Inspection 0999*1.) DOUBLE LUGING AT SERVICE PEDISTAL. 2.) SPLIT BOLT LISTED FOR RUN & TAP ONLY. 3.) BONDING JUMPER UNDER SIZED 4.) FEEDER JUMPERS UNDER SIZED. 5.) BONDING GROUNDS NEED TO BE CONNECTED TO NEUTRAL.