Inspection Status: Approved
Inspection History: MOBILE HOME ELECTRICAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/14/2001 |
MOBILE HOME ELECTRICAL |
|
Approved |
A.C. DUCT MUST BE 4" ABOVE EARTH |
| 11/26/2001 |
MOBILE HOME ELECTRICAL |
|
Partial Approval |
IVRS - Inspection 0000*1.) DOUBLE & TRIPLE LUGING AT MAIN PEDESTAL. 2.) SPLIT BOLT HAS TO MANY CONDUCTORS: TRY MULTI LUG ASSEMBLY. 3.) FEEDER JUMPERS UNDER SIZED. |
| 11/20/2001 |
MOBILE HOME ELECTRICAL |
|
Denied |
IVRS - Inspection 0999*1.) DOUBLE LUGING & TRIPLE LUGING AT MAIN PEDISTAL 2.) SPLIT BOLTS LISTED FOR RUN & TAP ONLY 3.) CLEAN SURFACE UNDER LUG 4.) CAN NOT USE SHEET METAL SCREW FOR GROUNDING. |