Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: MOBILE HOME ELECTRICAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/08/2001 |
MOBILE HOME ELECTRICAL |
|
Approved |
IVRS - Inspection 0000* |
| 10/03/2001 |
MOBILE HOME ELECTRICAL |
|
Denied |
IVRS - Inspection 0999*1.) DANGEROUS IMPROPER CONNECTION TO ELECTRIC PEDISTAL. IT IS THE PARK OWNERS RESPONSIBILITY TO PROVIDE CORRECT 40 AMP BREAKER AND CONNECT IT TO PLUG RECEPTACLE @ PEDISTAL. ALL HOME OWNER SHOULD DO IS PLUG IN HIS TRAILER. 2.) YOU MAY NOT BURY 40 AMP HOME SUPPLY CORD 3.) INSTALL SMOKE DETECTORS IN BEDROOMS 4.) INSTALL G.F.I. PLUG RECEPTACLE IN BATHROOM, BY WASHING MACHINE AND BY WASHING KITCHEN SINK. |