Permit: T01MH00224

Parcel: 115171660


Addresses:

1380 W EL RIO DR

Inspection Status: Approved

Inspection History: MOBILE HOME ELECTRICAL

Date Description Inspector Results Comments
05/18/2001 MOBILE HOME ELECTRICAL Approved IVRS - Inspection 0000*
05/17/2001 MOBILE HOME ELECTRICAL Denied IVRS - Inspection 0999*
05/16/2001 MOBILE HOME ELECTRICAL Denied IVRS - Inspection 0999* 1) ACORN CLAMP ON GROUND ROD HAS BEEN MODIFIED SINCE PEDISTAL INSP. WAS DONE. USE CLAMPS AS LISTED.
2) TERMINATION OF NEUTRAL BELONGS ON NEUTRAL BUS IN PEDISTAL 3) IMPROPER DOUBLE LUGGING OF EQUIPMENT GROUNDING CONDUCTORS IN SUB PANEL 4) UNAPPROVED EXTERIOR OUTLED ADDED TO EXTERIOR AT SUB PANEL 5) ALL ELECTRIC FIXTURES TO BE INSTALLED