Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Denied
Inspection History: MOBILE HOME PLUMBING
Permit Number - T01MH00199
Inspection Description - MOBILE HOME PLUMBING
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2001 | MOBILE HOME PLUMBING | Denied | IVRS - Inspection 0999* 1) USE 2 WAY CLEAN OUT NOT A "T". 2) SEAL AROUND DRAIN CONNECTION | |
04/24/2001 | MOBILE HOME PLUMBING | Denied | IVRS - Inspection 0999* 1) NEED PROPER GAS CONNECTOR FLEX LINE. 18" LENGTH 2) NEED 2 WAY CLEANOUT IN SEWERLINE. 3) NEED ISOLATION UNION IN GAS LINE AT SHUT OFF VALVE. 4) CHANGE PVC WATER LINE TO GALVANIZED PIPE 3' ON BOTTOM AND 2' RISER 5) INSTALL COVERS IN ALL UNUSED OPENINGS IN THE ELEC. SERVICE PANEL. | |
04/16/2001 | MOBILE HOME PLUMBING | Denied | IVRS - Inspection 0999* 1) IMPROPER USE OF FITTINGS ON DRAIN AND POTABLE 2) IMPROPER USE OF HOSE AS WATER SUPPLY |