Inspection Status: Denied
Inspection History: MOBILE HOME PLUMBING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/01/2001 |
MOBILE HOME PLUMBING |
|
Denied |
IVRS - Inspection 0999* 1) USE 2 WAY CLEAN OUT NOT A "T". 2) SEAL AROUND DRAIN CONNECTION |
| 04/24/2001 |
MOBILE HOME PLUMBING |
|
Denied |
IVRS - Inspection 0999* 1) NEED PROPER GAS CONNECTOR FLEX LINE. 18" LENGTH 2) NEED 2 WAY CLEANOUT IN SEWERLINE. 3) NEED ISOLATION UNION IN GAS LINE AT SHUT OFF VALVE. 4) CHANGE PVC WATER LINE TO GALVANIZED PIPE 3' ON BOTTOM AND 2' RISER 5) INSTALL COVERS IN ALL UNUSED OPENINGS IN THE ELEC. SERVICE PANEL. |
| 04/16/2001 |
MOBILE HOME PLUMBING |
|
Denied |
IVRS - Inspection 0999* 1) IMPROPER USE OF FITTINGS ON DRAIN AND POTABLE 2) IMPROPER USE OF HOSE AS WATER SUPPLY |