Permit: T01MH00172

Parcel: 140373240

Inspection Status: Approved

Inspection History: MOBILE HOME SITE LOC./SET-UP

Date Description Inspector Results Comments
04/13/2001 MOBILE HOME SITE LOC./SET-UP Approved IVRS - Inspection 0000*
04/04/2001 MOBILE HOME SITE LOC./SET-UP Denied IVRS - Inspection 0999* LIC# 5841, TAG 278247,
SN 8022, HUD ARZ 235588. SKIDS ARE NOT DESIGNED TO BE USED AS CHASSIS SUPPORT. PIERS MUST CONTACT CHASSIS