Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T01ME00857
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/04/2002 | MECHANICAL - FINAL | Approved | ||
| 01/02/2002 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection 0000*1.) CANNOT USE GREENFIELD FLEX OUTDOORS FOR HI-VOLTAGE WIRING REPLACE WITH SEAL TITE OR EMT. 2.) NEED CONNECTOR REAR OF HI-VOLTAGE SWITCH INTO UNIT. SHARP EDGE OF HOLE IN UNIT CASING WILL CUT WIRE. 3.) TERMINATE CONDENSATE DRAINS, OK TO TERMINATE DRAINS INTO ROOF GUTTERS IF DOWN SPOUT CONTINUES DOWN TO GROUND. CORRECT/RECALL. |