Permit: T01ME00758

Parcel: 13340001B

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T01ME00758

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/27/2002 MECHANICAL - FINAL Approved IVRS - Inspection 0000*ALL CORRECTIONS HAVE BEEN MADE.
02/05/2002 MECHANICAL - FINAL Denied IVRS - Inspection 0999*CAME TO DO FINAL INSPECTION ON CORRECTIONS MADE ON NEW SYSTEM. FOUND UNIT & DUCT HAD BEEN REPLACED. 1.) STRAP FLEX DUCT UP OFF OF DIRT MIN. 4." SPACE STRAPS MAX. 4'. 2.) INSULATE ALL BARE METAL UNDER HOME, TWYES, START COLLARS. RECALL FOR FINAL INSPECTIONS.
09/13/2001 MECHANICAL - FINAL Denied IVRS - Inspection 0999*1.) GAS PIPE CANNOT RUN IN FRONT OF SERVICE ACCESS PANELS.2.) PLUMBERS TAPE IS NOT AN APPROVED METHOD FOR STRAPPING UP GAS PIPE. RECOMMEND RUNNING GAS PIPE ALONG SIDE OF ELEC. CONDUIT. RECALL FOR FINAL INSPECTION.