| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2001 | MECHANICAL - FINAL | Approved | IVRS - Inspection 0000*ON THE LAST INSPECTION CONDENSATE DRIPPING OVER THE EDGE OF THE ROOF, YOU WERE IN VIOLATION OF SEC. 310.4 NOTE #4 1994 UMC MODIFICATION THE CONTRACTOR IS RESPONSIBLE FOR THE RE-INSPECTION FEE, NOT THE HOMEOWER. WHY DID THE HOMEOWNER HAVE TO BUY THE PERMIT? YOU DIDNT EVEN HAVE A PERMIT UNTIL YOU GOT CAUGHT BY THE ELECTRICAL INSPECTOR. | |
| 06/25/2001 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0999* | |
| 06/22/2001 | MECHANICAL - FINAL | Denied | PLEASE ADVISE YOUR A/C CONTRACTOR THAT CONDENSATE DRAINS CANNOT BE TERMINATED DUMPING OVER THE SIDE OF A ROOF FACA BOARD.THIS IS INCORRECT AND CANNOT BE ACCEPTED.PLEASE CALL YOUR CONTRACTOR AND ADVISE HIM A CORRECTION IS NECESSORY, AND I'M ALSO GOING TO CHANGE A REFEE BECAUSE THEY KNOW THAT THIS IS INCORRECT, UNACEPTABLE AND DO NOT NEED TO BE ADVISED OF THIS ISSUE. | |
| 06/18/2001 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0999*WHEN TERMINATING CONDENSATE INTO A WASTE VENT, THE VENT MUST BE MIN.2".PAINT EXPOSED PVC WITH LATEX PAINT.SPRAY EMANEL WILL NOT BE ACCEPTED. CORRECT AND RECALL FOR FINAL INSPECTION. |