Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/12/2001 |
MECHANICAL - FINAL |
|
Approved |
IVRS - Inspection 0000*ALL CORRECTIONS HAVE BEEN MADE. |
| 05/15/2001 |
MECHANICAL - FINAL |
|
Denied |
IVRS - Inspection 0999* IF TERMINATING CONDENSATE INTO THE SIDE OF A WASTE VENT, YOU MUST USE AN APPROVED FITTING OR OVER THE TOP WITH A 3/4" TEE |
| 04/27/2001 |
MECHANICAL - FINAL |
|
Denied |
IVRS - Inspection 0999* 1) YOU CANNOT TERMINATE A CONDENSATE DRAIN INTO A WASTE VENT SMALLER THAN 2" 2) GAS FLEX CONNECTOR NOT ADEQUATE SIZE FOR 100,000 BTU. SEE TABLE 3-D-2 1994 UMC FOR PROPER SIZING |