Permit: T01ME00361

Parcel: 134182110

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
07/12/2001 MECHANICAL - FINAL Approved IVRS - Inspection 0000*ALL CORRECTIONS HAVE BEEN MADE.
05/15/2001 MECHANICAL - FINAL Denied IVRS - Inspection 0999* IF TERMINATING CONDENSATE INTO THE SIDE OF A WASTE VENT, YOU MUST USE AN APPROVED FITTING OR OVER THE TOP WITH A 3/4" TEE
04/27/2001 MECHANICAL - FINAL Denied IVRS - Inspection 0999* 1) YOU CANNOT TERMINATE A CONDENSATE DRAIN INTO A WASTE VENT SMALLER THAN 2" 2) GAS FLEX CONNECTOR NOT ADEQUATE SIZE FOR 100,000 BTU. SEE TABLE 3-D-2 1994 UMC FOR PROPER SIZING