Permit: T01ME00072

Parcel: 136061320


Addresses:

2201 S AIDA AV

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
02/12/2001 MECHANICAL - FINAL Approved IVRS - Inspection 0000* ALL CORRECTIONS HAVE BEEN MADE
02/09/2001 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection 0000*
01/31/2001 MECHANICAL - FINAL Denied IVRS - Inspection 0999*
USE AN APPROVED FITTING WHEN TERMINATING CONDENSATE INTO A WASTE VENT. VENT MUST BE MIN 2".
VENT ON CONDENSATE DRAIN LINE UST BE DOWNSTREAM OF THE TRAP
MARK DATA PLATE W/THE PROPER HEAT STRIP INSTALLED AND FUSE UNIT ACCORDINGLY.
CORRECT AND RECALL FOR FINAL