Permit: T01EL02874

Parcel: 136190540


Addresses:

3334 S MEAD AV

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
02/05/2002 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection 0000*
01/31/2002 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0215*1.) PLEASE REFER TO THE INFORMATION STICKER ON PANEL COVER. REGARDING 2.) THE USE OF CIRCUIT BREAKERS OTHER THAN THOSE LISTED ON THE INFO. TAG IS PROHIBITED. EXCHANGE THE NON LISTED ONES IN PANEL WITH ONES OF THE NUMUFACTURER & TYPE LISTED BY CUTLER HAMMER.
01/30/2002 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0220*1.) THE N.E. CODE (99) REQUIRES ALL METAL PIPING ON PREMESIS BE BONDED TO THE EQUIPMENT GROUND. THIS MAY BE ACCOMPLISHED BY INSTALLING A GROUND JUMP WIRE FROM THE COLD WATER PIPE TO THE GAS PIPE. CORRECT & RECALL.
01/29/2002 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0920*1.) NO ACCESS TO BACKYARD. 2.) NO ANSWER AT FRONT DOOR. ARRANGE TO LEAVE GATE OPEN OR BE HOME TO ESCORT THE INSPECTOR ONTO THE PROPERTY.