Permit: T01EL02775

Parcel: 125060100


Addresses:

1915 E 3RD ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/28/2001 ELECTRIC - FINAL Approved IVRS - Inspection 0000*OK TO CLEAR OK CABLE DROP.
11/21/2001 ELECTRIC - FINAL Denied IVRS - Inspection 0999* 1) VERIFY GAS BOND. 2) PERMANENTLY LABEL BREAKERS. 3) USE BREAKERS LISTED FOR USE BY MANUFACTURE. 4) CAN NOT USE OLD DISCONNECT AS JUNTION BOX- USE APPROVE BOX. 5) PROTECT EMT FROM CORROSION WHERE IN CONTACT WITH THE EARTH. 6) WHERE DOES EMT RUN GO TO? UNBURY CONDOIT TO INSPECT DEPTH. 7) VERIFY WRATHER PROOF SEAL FOR 1 1/4" CONDUIT. 8) STRAP CONDUIT AS PER CODE.