Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 01/15/2002 |
ELECTRIC - RECONNECT |
|
Approved |
IVRS - Inspection 0000* |
| 12/04/2001 |
ELECTRIC - RECONNECT |
|
Denied |
IVRS - Inspection 0999*BE ADVISED 1. PLUGIN REEPTACLES WHICH SERVE THE KITCHEN COUNTERS MUST BE GFI. THE BATHROOM PLUGIN RECEPTACLE MSUT ALSO BE GFI. 2.) THE 220VOLT CABLE SERVING THE DRYER OUTLET MUST BE SHORTENED AND STAPLED CLOSE TO THE 2 X 4 SUPPORT. 3.) THE ELECTRICAL CIRCUIT BREAKERS MUST BE MARKED WITH AREA SERVED E.G. KITCHEN, LIV. RM ETC. CORRECT & RECAL INSPECTION. |