Permit: T01EL02601

Parcel: 136232800


Addresses:

3552 S AUSTIN PL

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
01/15/2002 ELECTRIC - RECONNECT Approved IVRS - Inspection 0000*
12/04/2001 ELECTRIC - RECONNECT Denied IVRS - Inspection 0999*BE ADVISED 1. PLUGIN REEPTACLES WHICH SERVE THE KITCHEN COUNTERS MUST BE GFI. THE BATHROOM PLUGIN RECEPTACLE MSUT ALSO BE GFI. 2.) THE 220VOLT CABLE SERVING THE DRYER OUTLET MUST BE SHORTENED AND STAPLED CLOSE TO THE 2 X 4 SUPPORT. 3.) THE ELECTRICAL CIRCUIT BREAKERS MUST BE MARKED WITH AREA SERVED E.G. KITCHEN, LIV. RM ETC. CORRECT & RECAL INSPECTION.