Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/11/2001 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*APPROVED OK TO CLEAR RECONNECT WILL NOTIFY TEP. |
| 10/10/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*1. SERVICE REQUIRES IT'S OWN GROUNDING ELECTRODE SYSTEM 2. A BUSYING IS REQUIRED FOR THE ENTRY NIPPLE 3. NEED GROUNDING BUSHING AT PANEL BOARD ENTRY. 4. ISO GROUNDS & NEUTRALS 5. WILL NEED TO SEE FINAL APPROVAL ON * NEW ROOF/TRUSSES & PLUMBING 6. PLEASE CALL 791-5550 EX. 136 & LEAVE INFORMATION OF TYPE OF VSEAGE FOR THIS SPACE. * NOTE NEW ROOF/TRUSSES. |