Permit: T01EL02432

Parcel: 111073230

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
01/08/2002 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection 0000*OK TO CLEAR UNIT #6.
12/27/2001 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0920*UNITS NEED TO BE OPEN.
12/20/2001 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection 0000*1.) DOUBLE LUGING AT GROUNDED TERMANAL. 2.) LOOSE SEAL TITE CONNECTIONS 3.) PROVIDE BONDING DEVICES FOR METAL RACEWAY CONTAINING GROUNDING ELECTRODE CONDUCTOR 250-64.
12/06/2001 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0245*UNITS 6 & 7 TO COMPLY WITH ART 250-32 NEC REQUIRES GROUNDING ELECTRODE SYSTEM SEPERATE BLD.
11/23/2001 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0245*SEE WRITE UP FOR UNIT #5.
11/21/2001 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0999*DENIED SEE WRITE UP FOR #5.
10/24/2001 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0245*SEE - WRITE UP FOR UNIT #5.