Permit: T01EL02413

Parcel: 107131270


Addresses:

2620 N BALBOA AV #A

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
10/01/2001 ELECTRIC - RECONNECT Approved IVRS - Inspection 0000*
09/30/2001 ELECTRIC - RECONNECT Denied IVRS - Inspection 0999*1.) GROUNDED RECEPTACLES ON GROUNDED SYSTEM 2.) GROUND AND NEUTRALS TO BE SEPARATED AT SUB-PANEL 3.) DOUBLE LUGING OF NEUTRALS AT SUBPANEL 4.) BRAKERS USED ARE NOT LISTED FOR USE IN THIS SUB PANEL. 5.) PLEASE RELOCATE SMOKE DETECTOR IN BEDROOM NO CLOSER THAN 3' FROM A REGISTER OR 18" FROM A CORNER 6.) KITCHEN HAS BEEN REQUIRED NEED 2 CIRCUITS (20 AMP) TO SUPPLY COUNTER TOPS 210-52 7.) SECURE ROMEX CABLE ENTRUG HOOD TO UNIT 8.) NEED LICENSED ELECTRICAL CONTRACTOR TO PERFORM WORK HAVE CONTRACTOR CONTACT US WITH THIS INFORMATION.