Permit: T01EL02407

Parcel: 122154120


Addresses:

3405 E LESTER ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/04/2001 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
09/27/2001 ELECTRIC - FINAL Denied 1.) IMPROPER WIRING METHOD FOR GROUND IN J-BOX, USE MECH, LUG, NO SHEET METAL SCREWS, PER ART 250 N.E.C.