Permit: T01EL02303

Parcel: 123120140


Addresses:

1448 E HAMPTON ST


Inspection Status: Approved

Inspection History: ELECTRIC - CABLE DROP

Permit Number - T01EL02303

Inspection Description - ELECTRIC - CABLE DROP

Inspection Status - Approved

Date Description Inspector Results Comments
09/19/2001 ELECTRIC - CABLE DROP Approved IVRS - Inspection 0000*
09/13/2001 ELECTRIC - CABLE DROP Denied IVRS - Inspection 0999*1.) NEED PERMANENT METAL ADDRESS LABEL. 2.) BOND TO GAS PIPING 3.) USE APPROVED FITTING AND BONDING METHOD AT L.B. 4.) USE PROPER SPLICE METHODS FOR CONNECTING CONDOCTORS NEUTRAL. 5.) ROMEX IN NOT APPROVED FOR USE IN A RACEWAY SYSTEM 6.) USE ANTIOXIDE COMPOUND WITH ALUMINUM CONDUCTORS 7.) USE BREAKERS APPROVED FOR USE BY MANUFACTURE. 8.) RE-TIGHTEN MAIN NEUTRAL CONNECTION 9.) PLEAS VERIFY LICENSED ELECTRICAL CONTRACTOR.