Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 10/10/2001 |
ELECTRIC - RECONNECT |
|
Approved |
IVRS - Inspection 0000* |
| 09/17/2001 |
ELECTRIC - RECONNECT |
|
Denied |
IVRS - Inspection 0245*CORRECTIONS REQUIRED 1.) PATIO/PORCH REMOVE ZIP CORD WIRING TO FLOURESCENT FIXTURE. 2.) STRAIGHTEN ROMEX FOR FLOOD LITES AND STAPLE TO WOOD JOISTS TO KEEP FROM SAGGING.3.) REMOVE CONDUIT AND WIRING TO OLD B.B.Q. AREA 4.) INSTALL SMOKE DETECTORS IN ALL BEDROOMS. 5.) INSTALL ANY MISSING PLUGS SWITCHES AND COVER PLATES 6.) INSTALL GFI RECEPTACLES IN KITCHEN ABOVE COUNTERS RECALL WHEN COMPLETE. |