Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date |
Description |
Inspector |
Results |
Comments |
| 09/11/2001 |
ELECTRIC - SERVICE UPGRADE |
|
Approved |
IVRS - Inspection 0000*OK TO CLEAR. |
| 09/06/2001 |
ELECTRIC - SERVICE UPGRADE |
|
Denied |
IVRS - Inspection 0999*1.) NEED PERMANENT METAL ADDRESS LABEL. 2.) GROUND RODS TO BE MINIUM G" APART 3.) SECURE BONDING CONDOCTOR TO STRUCTURE. 4.) RISER HARDWARE TO BE MININUM 1/4" 5.) USE SEALING DEVICE AT ENTRANCE ON TOP OF PANEL & AT BOND WIRE. 6.) USE APPROVED FITTING AT LB-CHASENIPPLE NOT APPROVED ALSO BOND AROUND CONCENTRICS 7.) INSTALL LOCK NUTS CORRECTLY. 8.) SECURE CONDUITS AS PER CODE. 9.) NEED GROUNDING ELECTRODE SYSTEM SECOND BUILDING 10.) IDENTIFY NEUTRAL CLOSER TO WEATHER HEAD. 11.) HAVE LICENSED CONTRACTOR CONTACT ME BEFORE NEXT INSPECTION. |
| 08/31/2001 |
ELECTRIC - SERVICE UPGRADE |
|
Denied |
IVRS - Inspection 0245* |