Date Description Inspector Results Comments
09/06/2001 ELECTRIC - FINAL Approved IVRS - Inspection 0000*OK TO CLEAR.
08/30/2001 ELECTRIC - FINAL Denied IVRS - Inspection 0999*MAIN GROUNDING ELECTRODE CONDUCTOR MUST BE ATTACHED TO NEUTRAL BAR (OR USE AND SIZE A MAIN BONDING JUMPER) ALL 20 AMP CIRCUIT IN SIDE HOUSE PLEASE INSTALL A WATER BOND AND GROUNDING ELECTRODE SYSTEMS.