Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
Permit Number - T01EL02160
Inspection Description - ELECTRIC - SERVICE UPGRADE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/31/2001 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection 0000* | |
08/29/2001 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection 0245*NOTES 1.)PLEASE READ LAST INSPECTION WRITE-UP 2.) 1/4 BOLTS.3.) INSTALL CONNECTOR WITH BUSHING OR AT LEAST AN ANTI SHORT BUSHING WHERE FEEDER CABLE EXITS FLEX CONDUIT. | |
08/28/2001 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection 0245*NOTES: 1.) HAS NOT COMPLIED WITH ITEMS #2. 2.) RISER SUPPORTS SHOULD HAVE 1/4" BOLTS MIN. TOP SUPPORT APPEAR TO HAVE DRYWALL SCREWS (NOT STROP ENOUGH) | |
08/23/2001 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection 0999*1.) SUPPORT RISER BELOW ROOF/PORCH. 2.) PROTECT CONDUCTORS/CABLE ENTERING CONDUIT. 3.) SEALING DEVICE NEEDED AT ENTERY ON TOP OF PANEL. 4.) NEED WEATHER PROOF DEVICE FOR DRYER. 5.) USE APPROVED WETHER PROOF FITTINGS. 6.) BOND JUNCTION BOX ENCLOUSER 7.) IDENTIFY NEUTRAL CLOSER TO WEATHER HEAD 8.) NEED GAS BOND. |