Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01EL01908

Parcel: 122163020


Addresses:

3865 E EDISON PL


Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Permit Number - T01EL01908

Inspection Description - ELECTRIC - SERVICE UPGRADE

Inspection Status - Approved

Date Description Inspector Results Comments
10/22/2002 ELECTRIC - SERVICE UPGRADE Approved
07/20/2001 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0999*1.) SERVICE MUST HAVE A PERMANENT ADDRESS ON IT NO PEN OR MARKER 2.) HIGHEST AVAILABLE CIRCUIT BREAKER SPACE CAN ONLY BE 6"7" HIGH. 3.)NOW REQUIRED TO HAVE A GAS LINE BOND 4.) #10 ROMEX EXPOSED UNDER ROOF TO BE IN BOX AND CONDUIT (ROMEX HAS TO HAVE PHYSICAL PROTECTION 5.) TWO BOTTOM 20 AMP CIRCUIT BRAKERS ARE SEIMENS MUST USE SAME TYPE AS PANEL 6.) GFI RECEPTACLE TO BE SUPPORTED. PLS CORRECT AND RECALL. 7.) NEED TO USE A LEAST 1/4" HARDWR TO SUPPORT RISER 1/4" LAG SCREWS OR EQUIVALENT.