Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/20/2001 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*OK TO CLEAR RECONNECT ADDRESS & J X BOX WIRES. |
| 07/18/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) INSIDE PANEL HAS AN EAGLE TAP ON BUS TO FEED DRY SW UNPROTECTED #12 ON 60AMP BUS ROMEX. TO DRYER RUN THUR OPEN HOLE NO CLAMP. 2.) DRYER SW HAS #12'S ON 30 A BREAKER #' 12'S ONLY GOOD FOR 20 AMPS ROMEX TO DRYER SW NOT CLAMPED. 3.) REPLACE BROKEN RECEPTACLE SW BED ROOM 4.) INSTALL BATTERY IN SMOKE DETECTOR. 5.) OPEN WIRING METHODS TO CARPORT NOT APPROVED CORRECT OR REMOVE 6.) ADDRESS SERVICE. |