Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/30/2001 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*OK TO CLEAR OK CABLE DROP. |
| 10/18/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0920*NOTES NO ANSWER AT DOOR LOCK UP DOG. |
| 07/24/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245*1.BOND GAS PIPING. 250-104 N.E.C. 2.) BOND J-BOX 250-148 N.E.C. 3.) INSTALL BUSHING TO PROTECT CONDUCTORS FROM ABRAISION 300-15C 300-16 N.E.C. 4.) INSTALL BOND BUSHINGS 250-94 N.E.C. 5.) #12 GROUND WIRE NOT GROUNDED. 6.) WIRING RUN OUT TO STORAGE SHED & GARAGE (CAR PORT) TO BE ON GFCI CIRCUIT BREAKER. |