Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01EL01762

Parcel: 11706072A


Addresses:

218 N 4TH AV


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T01EL01762

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/24/2001 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
07/17/2001 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*1.) NEED TO BOND TO GAS 2.) NEED BOND BUSHING METER CAN 3.) NEED REJECTION CLIPS 4.) SEPERATE GROUND & NEUTRAL 5.) NEED TO SEE CONNECTIONS TO SUB PANEL.