Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/11/2001 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 07/06/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) INSTALL CORRECT FUSING IN PANEL 15-20-30AMPS NONE INSTALLED CURRENTLY 2.) INSTALL GFI RECEPTACLES AT 2 RECEPTACLIES BY KITCHEN SINK ONCE THEY HAVE BEEN CHANGED THE MUST BE GFI TYPE. 3.) FURNACE HAS TO BE FIXED OR REPLACED #14 WIRE- 15AMP #12 WIRE 20 AMPS #10 WIRE 30 AMPS |