Permit: T01EL01606

Parcel: 12311002A


Addresses:

1541 E LINDEN ST


Inspection Status: Partial Approval

Inspection History: ELECTRIC - FINAL

Permit Number - T01EL01606

Inspection Description - ELECTRIC - FINAL

Inspection Status - Partial Approval

Date Description Inspector Results Comments
07/24/2001 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*1.) USE APPROVED FITTINGS FOR A/C DISCONNECT.
07/05/2001 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*1.) NEED GAS BONDING JUMPER AROUND UNION FITTING TO INTERIOR PIPING BOND COVERS 2ND BUILDING ONLY 2.) VERIFY PERMIT FOR A/C INSTALLATION.
06/25/2001 ELECTRIC - FINAL Denied IVRS - Inspection 0999*1.) NEED GAS BOND 2.) LOOSE SEAL TITE FITTING 3.) NEED GROUNDING EQUIPEMENT CONDUCTOR IN CONDUIT SYSTEM DUE TO BROKEN FITTINGS. 4.) 10 NEUTRAL CONDUCTOR CLOSER TO WEATHER HEAD 5.) USE CORRECT SIZE LUGS FOR CONDUCTORS CAN NOT WHITTLE WIRE DOWN TO FIT 6.) USE CORRECT SUPPORT FOR RISER STRAP.