Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - CABLE DROP
Permit Number - T01EL01515
Inspection Description - ELECTRIC - CABLE DROP
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/17/2001 | ELECTRIC - CABLE DROP | Approved | IVRS - Inspection 0000* | |
06/13/2001 | ELECTRIC - CABLE DROP | Denied | IVRS - Inspection 0999*1)NEED JUCTION BOX-CNANOT USE OLD DISCONNECT AS JUNCTION BOX.2)USE APPROVED FITTINGS TO CONNECT L.B.-CHASE NIPPLE NOT APPROVED.3)HIGHEST MEANS OF DISCONNECTING NOT TO BE OVER 6'7".4)BOND JUNCTION ENCLOSURE.5)STRAP BURY GROUND WIRES-OK TO PUT GROUND RODS FLUSH.6)PLEASE VERIFY LICENSED ELECRICAL CONTRACTOR. |