Permit: T01EL01469

Parcel: 140230550


Addresses:

5711 S SOUTHLAND BL

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
06/21/2001 ELECTRIC - RECONNECT Approved IVRS - Inspection 0000*OK TO CLEAR RECON. WILL NOTIFY TEP 1.) INSTALL FLUE ON REAR UNIT WATER HEATER SEAL 1/2 HOLE ON TOP OF RECEPATACLE BACK UNIT BELOW PANEL.
06/18/2001 ELECTRIC - RECONNECT Not ready for Inspection IVRS - Inspection 0000*CANCELLED BY JUDY BOYCE
06/11/2001 ELECTRIC - RECONNECT Denied IVRS - Inspection 0999*REAR UNIT-1)REAL UNIT-DOUBLE LUGGING IN PNL.2)PROTECT ROMEX BELOW PNL AND USE CONNECTOR INTO BOX.3)BEDROOM REQUIRES SMOKE DETECTOR.4)COVER FOR RANGE AND REPLACE BROKEN RECEPTACLE.FRONT UNIT-1)INSTALL FIXTURE UN FURNACE ROOM.2)FRONT YARD SUPPORT BOX AND DEAD END WIRING.3)WEATHER PROOF COVER ON ROOF COOLER OUTLET.