Permit: T01EL01335

Parcel: 11522035A


Addresses:

1405 W EL RIO DR

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
02/15/2002 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection 0000*OK TO CLEAR.
12/31/2001 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection 0000*1.) PLEASE CLEAN UNDER GAS BOND CLAMP. 2.) BOND GROUND BAR TO NEUTRAL BAR 250-24. 3.) STRAP CONDUIT BELOW PANEL 4.) NEED PERMANENT ADDRESS LABEL. PLASTIC WILL DETERIORATE AFTER TIME IN THE SUN. 5.) CAN NOT USE L.B. A HEAD OF METER ON UNPROTECTED CONDOCTORS. SR-405 #7. JUNCTION BOX TO HAVE POWER COMPANY LOCK NOT OWNERS. HAVE A HAPPY NEW YEAR.