Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/25/2001 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 06/01/2001 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*1)1" SEALTITE FEEDER CONDUIT NOT SUPPORTED.2)PROVIDE GROUND WIRE IN NON-METER SEALTITE.3)CHASE NIPPLE NOT APPROVED WIRING METHOD TO ATTACH LB TO SERVICE PANEL USE CLOSE NIPPLE WITH LOCKNUTS AND BOND BUSHING, 250-94 NEC.4)DOUBLE LUGGING IN EXISTING DISCONNECT (OLD SERVICE DISC) NOT ALLOWED, DO NOT USE OLD DISCONNECT SWITCH FOR J-BOX.5)PERMIT AND INSPECTION REQUIRED FOR NEW AC UNIT.6)PROVIDE NAME AND PH# OF C-11 LICENSED CONRACTOR DOING WORK. |