Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01EL00831

Parcel: 137051120


Addresses:

4949 S 12TH AV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/12/2001 ELECTRIC - FINAL Approved IVRS - Inspection 0000* MUST REDO PERMANENT ADDRESS LABEL ON METER BASE ORIGINAL IS INKED IN ON ONE NUMBER