Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/11/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1) NEED GROUNDING ELECTRODE SYSTEM INSTALLED PER CODE. 2 RODS, WATER AND GAS BOND 2) WILL NEED A HANDLE TIE FOR 2 POLE BREAKER WILL REQUIRE HANDLE TIES 3) WILL NEED A LICENCED C-11 ELEC. CONTRACTOR |
|
| 04/06/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1) ADDRESS HOUSE(USE 3" HIGH NUMBERS) 2) THE WATER LINE HAS BEEN REPLACED WITH PVC PIPING AND YOUR GROUNDING SYSTEM HAS BEEN COMPRIMISED. USE GROUND WIRE LEFT FROM OLD SYSTEM TO USE AS AN INTERIOR WATER BOND AND YOU WILL NEED TO INSTALL A NEW GROUNDING ELECTRODE SYSTEM IE:RODS ETC... 3) AT SERVICE YOU NEED FILLER PLATES AND A TIE BAR ON 2 POLE BREAKERS 4) THE WROUGHT IRON BARS ON THE 2 BEDROOM MUST BE REMOVED OR MADE SO AS TO RENDER QUICK RELEASE FOR AN EMERGENCY 5) OPEN WATER HEATER ROOM 6) INSTALL SMOKE DETECTOR 7) REPAIR/REPLACE FURNACE RECEPTICLE |