Inspection History Details
Permit: T01EL00741
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/24/2001 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
| 04/17/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*FINISH # 3-5 OF PREVIOUS INSPECTION 1. WORKING CLEARANCES FOR OVERHEAD CONDUCTORS. | |
| 04/11/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1) CLEAN SURFACE UNDER LUG IN METER SOCKET 250-12 2) LABEL BREAKERS 3) NEED ANTI-OXIDE COMPOUND ON ALUMINUM CONDUCTORS 4) ANCHORS COMING OUT OF WALL 5) LOOSE LOCKNUT SERVICE NIPPLES 6) LOOSE LUG BONDING BUSHING |
|
| 04/06/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0945* COULD NOT LOCATE SERVICE- PLEASE LEAVE MESSAGE FOR NEXT INSP |