Permit: T01EL00687

Parcel: 133181120


Addresses:

7022 E 3RD ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/16/2001 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
04/03/2001 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000* 1) TIGHTEN GROUND ROD CLAMP (LOOSE) 2) 500 WATT QUARTZ FIXTURE IN BACKYARD IN VIOLATION OF CITY LIGHTING ORDINANACE#8210. OUTWARD DISPERSING LIGHT CANNOT BE OVER 50 WATTS 3) OTHER ELECTRICAL WORK NEEDS TO BE PERMITTED SUCH AS POOL WIRING, A/C UNIT, AND OTHER BRANCH CIRCUITING
04/02/2001 ELECTRIC - FINAL Denied IVRS - Inspection 0910* NO ONE HOME DOGS IN YARD.
PLEASE LOCK UP DOGS OR MEET INSP. ON SITE. ALSO A PERMIT AND INSP. ARE REQUIRED FOR ADDITIONAL OUTSIDE WIRING
03/30/2001 ELECTRIC - FINAL Denied IVRS - Inspection 0245* BOND BUSHING REQUIRED ON UG RISER (NO HUB INSTALLED)