Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/23/2001 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 04/25/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245* CHASE NIPPLES NOT APPROVED AS WIRING METHOD FOR SERVICES, USE CLOSE NIPPLE WITH LOCK NUT BOTH ENDS AND GROUND BUSHING 250-94 NEC |
| 04/19/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245*1. BOND GAS LINE (250-104) NEC 2. INSTALL PERMANENT ADDRESS LABEL # 9287 CITY ORDIN. 3. CUT OFF 1" CONNECTOR NOT APPROVED AS TERMINATION OF 1" LB. USE CLOSE NIPPLE WITH SEALING LOCKNUTS & BOND BUSHING. (250-94) ( TOP OF PANEL) 4. IT APPEARS GROUND RODS HAVE BEEN CUT OFF AT TOP, NEC. REQUIRES 8' IN GROUND. |