Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01EL00409

Parcel: 111083510


Addresses:

3529 E WATER ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/19/2001 ELECTRIC - FINAL Approved IVRS - Inspection 0000*