Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/09/2001 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 07/05/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245*1.) CHASE NIPPLES NOT ALLOWED AT TERMINATION INTO PANELS USE CLOSE NIPPLES LOCKNUT ON INSIDE AND OUT OF CABINATE AND BOND BUSHINGS OR BOND LOCKNUTS 250-94 NEC. 2.) INSTALL BOND BUSHINGS WHERE CONCENTRICS ARE USED. 3.) INSTALL CONNECTORS WITH BUSHED ENDS WHERE ROMEX EXITS STEEL CONDUIT SLEEVES 300-15 300-16 N.E.C |
| 04/16/2001 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000* OK TO CLEAR TEMP POWER OK CABLE DROP |
| 04/13/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245*NOTES: BOND LUCKNUTS FOR BUSHINGS REQUIRED PER 250-94 NEC |