Permit: T01EL00049

Parcel: 117081000


Addresses:

820 S 6TH AV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/02/2001 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
03/09/2001 ELECTRIC - FINAL Denied IVRS - Inspection 0999* 1) THE WHITE CONDUCTOR IS STILL BEING USED AS A HOT CONDUCTOR MUST BE TAPED B6 AT PANEL, DISCONNECT, RECEPTICLE AND J BOX. 2) WHEN RECEPTICLE COVER IS RAISED IT CAN NOT HAVE EXPOSED PARTS-THE OPENING AROUND THE RECEPTICLE RENDERS THE CONNECTIONS INSIDE EXPOSED. YOU WILL NEED TO TAKE CARE OF THIS TO GET A FINAL
02/16/2001 ELECTRIC - FINAL Denied IVRS - Inspection 0999* MET ON SITE WITH ELECTRICAN AND REVIEWED PROBLEMS WHICH NEED TO BE CORRECTED
01/25/2001 ELECTRIC - FINAL Not ready for Inspection USE CORRECT WIRING METHODS, PROPERLY IDENTIFY HIGH CIRCUIT, CANNOT HAVE 2 MALE CORD CAPS ON EXTENTION CORD, NEED A MALE AND FEMALE
USE SJ OR SO CORD
SOME WHRE IN CIRCUIT THERE HAS BEEN A TRANSFER FROM A GREEN WIRE TO HOT AND A WHITE WIRE TO HOT