Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T01CM06226
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/12/2003 | PLUMBING - ROUGH, SOIL | Approved | ||
09/26/2003 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999* | |
09/25/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ FISH AND GAME ABS UNDERGROUND OK. WATER TEST ONE RISER TO TEN FEET. OK TO COVER. | |
09/24/2003 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SOILS TOO WET FROM RAIN 2) DRYOUT TRENCH AND RECALL FOR INSPECTION | |
06/22/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000* 1) 2 BRANCHES FOR BATHROOM GROUPS OK. 2) SUBJECT TO REVISED APPROVED PLANS. 3) RED LINES ON AS BUILTS. 4) OK TO COVER. | |
06/16/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | 1) HAVE REVISED PLAN APPROVED BY PLANS EXAMINER. 2) HAVE ARCHITECT REVIEW WASTE AND VENT ISOMETRIC ON P5.01. IT DOES NOT MATCH PLAN VIEW ON P2.03 OR PLUMBERS INSTALLATION. PLEASE REVISE AND HAVE APPROVED BEFORE NEXT INSPECTION 3) OK TO COVER BRANCH PIPING AND CONNECTIONS TO MAIN -3 PLACES | |
06/13/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ 1) 4" AND 6" ABS UNDERGROUND INSTALLED PER APPROVED PLAN. TWO FOUR INCH BRANCHES FOR MASTER BEDROOM STUBBED UP ONLY 2) OK TO COVER 3) SUBJECT TO REVISED APPROVED PLAN | |
06/11/2003 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999*/ 1) SPECS REQUIRE CAST IRON WITH HUSKEE BONDS UNDERGROUNDS |