Permit: T01CM06214

Parcel: 128070020


Addresses:

651 S TAMPICO AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/26/2002 FRAMING Approved IVRS - Inspection 0000*
04/24/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) SECURE EXHAUST DUCT AT ATTIC 2) CROSS CONNECTION WATER SOFTNER 3) NAIL OFF ALL OVER FRAMING 4) OVER SPAN STUD WALL AT MASTER BATH ENTRY 5) CHECK TRUSS DRAWINGS FOR U.N.O. DETAIL F/D1 NOT AROUND UNDER COUNTER OVER HANGS MORE THAN 6" 8) NEED COMPLETE SET OF APPROVED STAMPED TRUSS DRAWINGS 9) CONTINOUS BEARING TRUSS PORCH TO HOUSE WALL NEED FIX.
03/27/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) TRUSS SHOP DRAWINGS NEED TO BE STAMPED BY CITY OF TUCSON 2) TRUSS DRAWINGS DO NOT MATCH TRUSS PROFILE INSTALLED 3) NOTCH OUT NON BEARING BOTTOM CHORD FRONT WALL H2 TRUSSES 4) H-3 TRUSSES VERT. MEMEBER MISSED BEARING BY 3" 5) WHAT IS * SYMBOL MEAN ON DRAWING ?
03/05/2002 FRAMING Not ready for Inspection TE UNDER MATH BUTTOM CHECK SO TRUSS CAN COME DOWN WHEN LOADED 5.) X BRACE TRUSSES AT EACH END 25' O" O.C. 6.) TWO TRUSS SHOWN AS 3 PT. BOARING ARE 2PT, 3 SPANING LONGER THAN DRAWING. 7.) CHECK FRONT BEAM # 2PT. BOARING 8.) GIRDER BEARING ON GARAGE M-POOL. 9 NEED GIRDER SHOP DRAWING.