Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/26/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/24/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) SECURE EXHAUST DUCT AT ATTIC 2) CROSS CONNECTION WATER SOFTNER 3) NAIL OFF ALL OVER FRAMING 4) OVER SPAN STUD WALL AT MASTER BATH ENTRY 5) CHECK TRUSS DRAWINGS FOR U.N.O. DETAIL F/D1 NOT AROUND UNDER COUNTER OVER HANGS MORE THAN 6" 8) NEED COMPLETE SET OF APPROVED STAMPED TRUSS DRAWINGS 9) CONTINOUS BEARING TRUSS PORCH TO HOUSE WALL NEED FIX. |
| 03/27/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) TRUSS SHOP DRAWINGS NEED TO BE STAMPED BY CITY OF TUCSON 2) TRUSS DRAWINGS DO NOT MATCH TRUSS PROFILE INSTALLED 3) NOTCH OUT NON BEARING BOTTOM CHORD FRONT WALL H2 TRUSSES 4) H-3 TRUSSES VERT. MEMEBER MISSED BEARING BY 3" 5) WHAT IS * SYMBOL MEAN ON DRAWING ? |
| 03/05/2002 |
FRAMING |
|
Not ready for Inspection |
TE UNDER MATH BUTTOM CHECK SO TRUSS CAN COME DOWN WHEN LOADED 5.) X BRACE TRUSSES AT EACH END 25' O" O.C. 6.) TWO TRUSS SHOWN AS 3 PT. BOARING ARE 2PT, 3 SPANING LONGER THAN DRAWING. 7.) CHECK FRONT BEAM # 2PT. BOARING 8.) GIRDER BEARING ON GARAGE M-POOL. 9 NEED GIRDER SHOP DRAWING. |