Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM06213

Parcel: 128070050


Addresses:

621 S TAMPICO AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/16/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/12/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) INSTALL ALL LATERAL BRACES 2) SOLID BEARING UNDER ALL 3 PT BEARING TRUSSES 3) TRUSS DRAWING SHOWS COMMON TRUSSES WITH NO 3 PT BEARING AT PORCH 4) NEED APPROVED HANGER GIRDER TO GIRDER 5) PUT A TEMP. LEG UNDER GARAGE GIRDER