Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM06208
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/27/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/26/2002 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ (SEE NOTE 3 BELOW) 1) DRYER VENT NOT TO CODE: (TO LONG) 2) NO TOP OUT ON SEWER PIPING 3) ALL OTHER APPROVALS WILL BE GRANTED WHEN ITEMS 1 AND 2 ARE COMPLETED | |
02/25/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT VENT IN REAR GARAGE WALL AND BOTTOM PLATE 2) DRYER VENT DUCT TO LONG PER IRC CODE 3) NO DRAINAGE TOP OUT FOR TEST 4) LOW GAS PRESSURE 5) BLOCK DUCT BOOT IN LIVING ROOM 6) SECURE GAS PIPE VERTICLES AT FURNACES 7) NEED VENT FAN IN HALL BATH UPSTAIRS 8) ADD FIRE BLOCKING AT HOT WATER FLUE AT ROOF 9) REMOVE ROOFING FROM FLUES |