Permit: T01CM06176

Parcel: 11706318B


Addresses:

250 S TOOLE AV


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM06176

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
02/12/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*1.) REC'D LETTER FROM ARCHETED APPROVING TYPE "M" 2.) DWV WATER TST OK 3.) NEED ADDITIONAL HANGERS ON 1 1/2 COPPEROVERHEAD 4.) STRAP AND SUPPORT AS NEEDED 5.) NEEDD TO SEE CLOSET FLANGES.
02/11/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) HAVE PLUMBER REVIEW PLUMBING PLAN NOTES AND INSTALL PER PLAN 2.) REVIEW CHART FOR HANGERS AND SUPPORTS CHAPTER 3 94 UPC 3.) NO WATER TEST ON ABS 4.) SEWER/HCS TIED INTO EXISTING OK.