Date Description Inspector Results Comments
02/13/2002 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
01/17/2002 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*/ 1) REVISION OF ARCHITECT SEALED PLANS NOT ALLOWED WITHOUT ARCHITECT APPROVAL AND SEAL 2) PLANS APPEAR TO BE MODIFIED WITHOUT APPROVAL 3) MAXIMUM 135 DEGREE OF CHANGE IN SEWER LINE WITHOUT CLEANOUTS HAVE BEEN EXCEEDED HAVE PLANS REVISED AND REAPPROVED TO INCLUDE ALL CLEANOUTS 4) ADDED DRAIN TO GARAGE NOT ON PLAN, REVISE PLAN TO ASBUILT AND HAVE APPROVED. PAY ADDITIONAL SEWER FESS 5) CLEANOUTS WILL BE REQUIRED ON MASTER BATH WATER CLOSET
01/16/2002 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) SEWER LINE NOT SUPPORTED AT HCS-BRDIGED 2) HCS COVERED WITHOUT INSPECTION-EXPOSE 3) SEWER DRAIN TO KITCHEN/BATH HAS GREATER THAN 135 DEGREE OF HORIZONTAL CHANGE WITHOUT CLEANOUTS 4) BRIDGING NOT ALLOWED 5) REVISE PLUBMING PLAN TO SHOW ALL REQUIRED CLEANOUTS