Date Description Inspector Results Comments
03/01/2002 SHEET ROCK NAILING Approved IVRS - Inspection 0000*
02/28/2002 SHEET ROCK NAILING Denied IVRS - Inspection 0999*1.) PLAN CALLS FOR 6 D NAILS IN SHEAR WALLS. IF SCREWS ARE USED. PLAN MUST BE REVISED AND SCREWS MUST COMPLY WITH R.C. TABLE 602.3 (1) AND YOU MUST PROVIDE 1CBO LISTING FOR SCREWS USED.