Permit: T01CM06163

Parcel: 110065880

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T01CM06163

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
02/13/2002 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
01/17/2002 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*/ 1) REVISION OF ARCHITECT SEALED PLUMBING NOT ALLOWED WITHOUT ARCHITECT APPROVAL AND SEAL 2) PLANS APPEAR TO BE MODIFIED WITHOUT ARCHITECT APPROVAL 3) MAIMUM 135 DEGREE OF CHANGE IN SEWER LINE WITHOUT CLEANOUTS HAVE BEEN EXCEEDED, HAVE PLANS REVISED AND APPROVED TO INCLUDE ALL CLEANOUTS MASTER BATH WATER CLOSET CLEANOUT NOT REQUIRED 4) ADDED DRAIN TO GARAGE REVISE PLAN AND PAY ADDITIONAL FEES
01/16/2002 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) LEAK AT COUPLING BETWEEN CLEANOUT AND HCS 2) SUPPORT SEWER LINE AT HCS-BRIDGED 3) DRAIN TO KITCHEN HAS GREATER THAN 135 DEGREE OF CHARGE REQUIRES CLEANOUT 4) HCS COVERED W/O INSPECTION-UNCOVER 5) NO PLANS/PERMIT ON SITE