Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/19/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 02/13/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) STUD OVER BORED IN EXCESS OF 60 PERCENT BY LAUNDRY BOX 2) SUPPORT HORIZONTAL PLUMBING DWV AT 4' ON CENTER 3) PROVIDE PLUMBING PLAN FOR ADDED LAUNDRY 4) ANCHOR AND HD BOLTS LOOSE 5) MASTER BATH OVER BORED STUD AND CLEANOUT CANNOT BE ENCLOSED IN WALL |
| 02/12/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PEX LEAKING AT BATH 2) LEAK AT KITCHEN ? 3) DAMPER MISSING AT EXHAUST FAN IN MASTER BATHROOM |